IntelliShock 10 (Plug-In) Energizer Kit
An energizer kit that runs off of 110V (plug-in) power. Plug the unit in at an outlet and carry the power to the fence via the insulated cable.
Kit Includes:
- IntelliShock 10 (1 joule) Energizer
- 100 ft roll of Insulated Wire
- 3 ft ground rod and clamp
- Digital Tester for fences & batteries
Plug unit into a 110V wall outlet, or connect to an external 12V battery. (Connectors included for both. See Specifications below.)
California Residents: Proposition 65 Information
Instructions/Diagrams:
Common Uses
Specs
Plug-in Kit* #1120102 |
Battery Kit* #1120103 |
Energizer Only #1120101 |
|
---|---|---|---|
IntelliShock 10 Energizer | ✔ | ✔ | ✔ |
(1) Ground Rod (galvanized) | 3 ft | 3 ft | |
(1) Ground Rod Clamp | ✔ | ||
(1) Hanging Nut | ✔ | ||
MaxiShock Insulated Cable | 100' roll | ||
Wiring Harness | ✔ | ✔ | |
110V AC Adapter | ✔ | ✔ | ✔ |
DC Battery Leads | ✔ | ✔ | ✔ |
Digital Tester | ✔ | ✔ |
Should power…**
- 2 miles of 3 strand cattle fence
- 3/4 mile of a 5-7 strand sheep fence
- 10 of the 164' sheep/goat nets
- 4-5 of the 164' poultry nets
Miscellaneous
- Requires a grounding system. Inadequate grounding is the most common failure in an electric fence system. We recommend 3 ft. of grounding for this energizer, included in the kit.
Energizer Specifications
- 1.00 released joules
- 1.00 joules in moist soils
- 0.32 joules in dry soils
- Pulses per minute: 38
- 12V DC draw: 31-90 mA/hr
- 110V draw is 4.5 watt per hour
- Impedance type: low – pulse type
- Load sensing/variable draw: yes
- Input: AC/DC
- 110V Adapter/Charger
- Operates the energizer as a 110V unit when near a wall outlet
- 12V DC Leads
- To connect energizer to an external battery (batteries sold separately)
How to Use
To use light tester WITHOUT ground probe
For Fence:- Touch the top of the tester to the electrified fence you wish to test.
- Push the button (if applicable).
- The tester will light up according to the voltage at that location on the fence.
- Turn off energizer.
- Disconnect ground wire and fence wire from energizer.
- Turn on energizer.
- Touch the top of the tester onto the top of the fence terminal on the energizer.
- Push the button (if applicable).
- The tester should light up to 6000 volts or more.
To use light tester WITH ground probe
For Fence:- Insert the probe of the tester into the soil.
- Remove your hand from the metal portion of the probe (to avoid a shock).
- To get a voltage reading, touch the metal clip (on the top of the tester) to the electrified fence you wish to test.
- The tester will light up according to the voltage at that location on the fence.
- Remove the tester from the fence and the probe from the soil. Do not remove the probe by pulling the insulated wire.
- Turn off energizer.
- Disconnect ground wire and fence wire from energizer.
- Turn on energizer.
- Touch probe from tester to ground terminal on energizer (be sure to hold onto the insulated wire and not the metal probe!)
- At same time touch the fence hook on tester to fence terminal on energizer.
- The tester should light up to 6000 volts or more.
Benefits
Troubleshooting
Start by measuring the voltage at the end of the fence line. If the voltage is below 3000V, follow these steps to determine if the problem is with the fence, or the energizer.
Test the energizer first!
- Turn off the energizer.
- Disconnect the wires going to the fence and ground stake/rod.
- Turn the energizer back on.
- Measure the voltage on the energizer between the two terminals (positive and negative) with a digital voltmeter or other high-voltage tester. Touch one end to “-“ (earth terminal) and the other end to “+” (fence terminal). The reading tells you how well the energizer is working without any other variables.
- If the tester reads below 5000V, then the energizer (or possibly the battery) is the problem. If the voltage is above 5000V, then the trouble lies with your fence.
If the energizer is at fault:
- Test the battery with a low-voltage tester; recharge if lower than 12.2 volts
- Check the grounding system
If the fence is at fault:
- Conductors touching another wire, steel post or the soil
- Broken or damaged insulators
Precautions
To Reduce Risk & Liability
- Never place your head or upper spine near an electrified wire. Accidental head or neck contact can occur when pushing a voltage probe into the soil. Be careful when doing so to avoid head-to-wire contact!
- Never attempt to step over or climb through an energized fence of any kind.
- Never encourage anyone to touch an electric fence.
Warranty
Listed below are recommended optional components or related items. Your particular situation may require alternative recommendations. Please call and talk to our consultants if there are any questions at 800-282-6631.
-
Energizer Solar Panels and Accessories
MaxiShock Double Insulated Cable, 100'
Item #164207 -Electric fence cable with thick layers of insulating for transporting high voltage pulses from the energizer to the fence line.
$38.00 -
Energizer Solar Panels and Accessories
MaxiShock Double Insulated Cable, 50'
Item #164204 -Electric fence cable with thick layers of insulating for transporting high voltage pulses from the energizer to the fence line.
$20.00 -
Fence Connectors and Accessories
Ground Rod, Galvanized, 6'
Item #151000 -Complete the circuit of your electric fence with galvanized grounds. No corrosion unlike copper rods.
$18.00 -
Fence Connectors and Accessories
T Ground Rod, 3' x 1/2"
Item #151210 -Provide a conductive ground circuit for your electric fence. Conductive t-grip is easy to install and remove.
$15.00 -
Fence Connectors and Accessories
Fence Fault Finder
Item #133500 -Tests electric fences and determine fault locations with the press of the button. Save time in the field and reduce troublesome electrical shorts.
$119.00 -
Fencing
Warning Sign
Item #346000 -Let passersby know that your fences are electrified with this easy-to-read electric fence warning sign.
$1.60
-
Energizer Solar Panels and Accessories
MaxiShock Double Insulated Cable, 100'
Item #164207 -Electric fence cable with thick layers of insulating for transporting high voltage pulses from the energizer to the fence line.
$38.00 -
Fence Connectors and Accessories
Stainless Steel Clamp
Item #151800 -Stainless steel hose clamp. Firmly holds negative leads from the energizer to the ground rod.
$1.30 -
Handling Equipment
Ground Rod and/or Connecting Pin, 3'
Item #151200 -Effectively ground energizers or firmly secure handling equipment. Galvanized pin is resilient to rust and wear.
$8.00 -
Energizers
IntelliShock 10 Energizer
Item #1120101 -Electric fence energizer with 1 joule of output suitable for most hobby farm fence applications.
$130.00 -
Fence Connectors and Accessories
Fence & Battery Digital Tester
Item #200010 -All-in-one fence tester checks the voltage of energizers, fences and 12V batteries. Simplify electric fence troubleshooting with one device!
$24.00
Write a Review
You must be logged in to leave a review. Please sign in.
Matthew W from Maine
Easy to set up. So far the scent is baiting the deer perfectly with none entering the garden.
David P from North Carolina
Worked beautifully. Easy to install. Added off/on switch at the gate. Premier’s phone in help were extremely helpful.
Kenyan H from North Carolina
This product is superior to all fencing I have ever used! My livestock are safe and sound and haven't made a single attempt to break free from the fenced area.
Setup is super easy, super fun!
I will always use PREMIER 1 for ALL my fencing supplies!
Chris N from North Carolina
Easy to set up and is working great. My husky, Suki, who is a chicken eater, got a nip on the nose from the fence, and I think that will cure her of approaching the fence in the future.
Elizabeth S from Georgia
This energizer was easy to install even though I have no experience with installing such things. I have only been using this product for a week so I can not speak on the durability or longevity of it.